The RY stainless steel heat transfer oil pump is designed for conveying high-temperature liquids without solid particles. It is suitable for thermal oil circulation and high-temperature liquid transfer systems where stable operation and reliable heat dissipation are required.
The pump is available with different main wetted-part material options according to the medium and operating temperature requirements. The source material lists three material categories: HT200, ZG230-450, and 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti.
The RY stainless steel heat transfer oil pump adopts a self-cooling structure, replacing the traditional water-cooling design. This helps simplify the pump structure, reduce overall size, lower operating cost, and support stable operation in thermal oil service.
The pump uses a combination of packing seal and mechanical seal. The packing seal is selected for high-temperature adaptability according to actual operating conditions. The product is mainly used for weakly corrosive high-temperature liquids without solid particles. The source material lists a maximum service temperature of ≤370°C, while the design-point performance range lists a temperature range of -20°C to 350°C.
Features & Advantages
- Designed for Thermal Oil Service: Suitable for high-temperature liquid transfer without solid particles.
- Self-Cooling Design: Eliminates the traditional water-cooling structure for a simpler and more compact pump layout.
- Stable Operation: Designed for continuous heat transfer oil circulation and industrial high-temperature liquid service.
- Material Options: Main wetted-part material options include HT200, ZG230-450, and stainless steel grades listed in the source material.
- Combined Sealing Structure: Uses packing seal and mechanical seal together for supported operating conditions.
- Wide Performance Coverage: Flow, head, and temperature ranges support multiple thermal oil system requirements.
Typical Applications
The RY stainless steel heat transfer oil pump is suitable for:
- Heat transfer oil circulation systems
- Thermal oil heating systems
- High-temperature liquid transfer
- Weakly corrosive high-temperature liquid transfer
- Industrial heating and temperature-control systems
Materials
The source material lists the following main wetted-part material categories:
- HT200
- ZG230-450
- 1Cr18Ni9Ti / 0Cr18Ni12Mo2Ti
The applicable corrosion resistance level and operating temperature depend on the selected material and the actual conveyed medium.
Performance Range
The following range is based on the design point provided in the source material:
- Flow Rate: 1–500 m³/h
- Head: 10–125 m
- Temperature Range: -20°C to 350°C
- Maximum Service Temperature Listed: ≤370°C
- Medium: High-temperature liquid without solid particles
Technical Parameters
| Model | Flow Rate m³/h | Head m | Speed r/min | Shaft Power kW | Motor Power kW | Efficiency % | Motor Frame |
|---|---|---|---|---|---|---|---|
| 15-15-100 | 3 | 10 | 2800 | 0.45 | 0.75 | 20 | 801 |
| 15-15-100A | 2 | 10 | 2800 | 0.36 | 0.55 | 18 | AO2-7122 |
| 15-15-100B | 1 | 10 | 2800 | 0.2 | 0.37 | 15 | AO2-7112 |
| 20-20-100 | 1 | 10 | 2800 | 0.09 | 0.37 | 26 | AO2-7112 |
| 20-20-125 | 1.5 | 22 | 2800 | 0.22 | 0.75 | 30 | 801 |
| 40-25-160 | 10 | 28 | 2900 | 1.72 | 2.2 | 45 | 90L |
| 25-25-160 | 3 | 27 | 2900 | 0.53 | 1.5 | 30 | 90S |
| 32-32-160 | 6 | 28 | 2900 | 0.85 | 1.5 | 50 | 90S |
| 50-32-160 | 12.5 | 30 | 2900 | 1.90 | 3.0 | 57 | 100L |
| 50-32-200 | 18 | 40 | 2900 | 3.92 | 5.5 | 50 | 132S1 |
| 50-32-200A | 16 | 32 | 2900 | 3.35 | 4 | 42 | 112M |
| 50-32-250 | 12.5 | 80 | 2900 | 6.2 | 11 | 44 | 160M1 |
| 65-50-160 | 20 | 32 | 2900 | 3.17 | 5.5 | 55 | 132S1 |
| 65-40-200 | 30 | 48 | 2900 | 6.3 | 7.5 | 62 | 132S2 |
| 65-40-200A | 25 | 35 | 2900 | 4.0 | 5.5 | 59 | 132S1 |
| 65-40-250 | 25 | 80 | 2900 | 10.3 | 15 | 53 | 160M2 |
| 65-40-250A | 20 | 51 | 2900 | 5.67 | 7.5 | 49 | 132S2 |
| 65-40-315 | 25 | 125 | 2900 | 18.9 | 30 | 45 | 200L1 |
| 65-40-31 | 22.5 | 100 | 2900 | 15.3 | 22 | 40 | 180M |
| 80-50-200 | 50 | 50 | 2900 | 9.7 | 15 | 70 | 160M2 |
| 80-50-200A | 45 | 40 | 2900 | 7.8 | 11 | 63 | 160M1 |
| 80-50-200B | 40 | 32 | 2900 | 6.37 | 7.5 | 55 | 132S2 |
| 80-50-250 | 50 | 80 | 2900 | 17.1 | 22 | 58 | 180M |
| 80-50-250A | 43 | 60 | 2900 | 12.8 | 15 | 55 | 160M2 |
| 80-50-315 | 50 | 125 | 2900 | 30.4 | 45 | 56 | 225M |
| 80-50-31 | 45 | 100 | 2900 | 23.6 | 30 | 52 | 200L1 |
| 100-65-200 | 100 | 50 | 2900 | 18.4 | 22 | 74 | 180M |
| 100-65-200A | 94 | 44 | 2900 | 16 | 22 | 70 | 180M |
| 100-65-200B | 87 | 38 | 2900 | 13.8 | 15 | 65 | 160M2 |
| 100-65-200C | 80 | 32 | 2900 | 11.8 | 15 | 59 | 160M2 |
| 100-65-250 | 100 | 80 | 2900 | 32.06 | 37 | 68 | 200L2 |
| 100-65-250A | 95 | 72 | 2900 | 29 | 37 | 64 | 200L2 |
| 100-65-250B | 90 | 65 | 2900 | 26.2 | 30 | 61 | 200L1 |
| 100-65-250C | 85 | 50 | 2900 | 20.3 | 30 | 57 | 200L1 |
| 100-65-315 | 100 | 125 | 2900 | 50.06 | 75 | 68 | 280S |
| 100-65-31 | 95 | 113 | 2900 | 45.23 | 55 | 64.63 | 250M |
| 100-65-315B | 90 | 100 | 2900 | 40.5 | 55 | 60.50 | 250M |
| 100-65-315C | 82 | 84 | 2900 | 34.76 | 45 | 54 | 225M |
| 125-100-200 | 200 | 50 | 2900 | 35.4 | 45 | 77 | 225M |
| 125-100-200A | 178 | 40 | 2900 | 26.6 | 37 | 73 | 200L2 |
| 125-100-250 | 200 | 70 | 2900 | 47 | 55 | 80 | 250M |
| 125-100-250A | 190 | 63 | 2900 | 41.6 | 55 | 78 | 250M |
| 125-100-250B | 180 | 57 | 2900 | 37.9 | 45 | 74 | 225M |
| 125-100-250C | 170 | 51 | 2900 | 32.15 | 45 | 72 | 225M |
| 125-100-250D | 150 | 70 | 2900 | 40 | 45 | 70 | 225M |
| 150-150-200 | 350 | 50 | 2900 | 60 | 75 | 80 | 280S |
| 150-150-200A | 313 | 40 | 2900 | 45 | 55 | 76 | 250M |
| 200-150-400 | 350 | 50 | 1450 | 61.8 | 75 | 78 | 280S |
| 200-150-400A | 330 | 45 | 1450 | 52.8 | 75 | 77 | 280S |
| 250-200-400 | 500 | 50 | 1480 | 86.2 | 110 | 79 | 315S |
| 250-200-500 | 500 | 80 | 1480 | 136 | 160 | 76.5 | 315M |
| 250-200-500A | 400 | 50 | 1480 | 75 | 90 | 73 | 280M |